Truma Oem Combi D6E Kit > 2022
OEM for professional installation only!
The Combi D 6E is structurally identical to the Combi D 6, the only difference being the integrated electric heating elements. The diesel version is equipped with a high-quality burner and therefore reliably heats the vehicle while driving.
· Can also be operated with an empty water tank
· Simple operation with the digital Truma CP plus (iNet ready) control panel or via iNet X System
· Optimum warm air distribution via four air outlets
· 10-litre stainless steel water tank
· Compact and space-saving, various installation options
· Heats the vehicle and water very quickly
· Uses little energy
· Integrated pressure sensor automatically controls the combustion air infeed
· Long service life thanks to efficient combustion control
· Automatic climate control possible in combination with a Truma air conditioner
· Heat Hybrid: integrated electric heating elements for additional electrical power
· 2 in 1: heats your vehicle and heats water at the same time
· For larger vehicles
Energy sources: Diesel as per EN 590
Rated heat output in diesel mode: 1000W/2000W/3000W/4000W/5000W/6000W
Rated heat output in electric mode: 900W/1800W
Rated heat output in mixed mode: max. 6900W
Fuel consumption: 0.1 – 0.6 l/h
Power consumption (at 12 V): operation of heater and water container: 0.4 – 8.1A
Power consumption (at 230 V): 3.9A/7.8A
Water capacity: 10 litres
Heating time (from approx. 15 °C to approx. 60 °C): Water container: approx. 20min.
Heating time (from approx. 15°C to approx. 60°C): Heater and water container acc. to EN 15033: approx. 80min.
Weight: 16.9kg
Dimensions (L x W x H): 510 x 450 x 300 mm
Installation dimensions (minimum dimensions–additional space must be provided for the gas connection. water connections and drain valve (L x W x H) depending on the installation situation): 540 x 500 x 350mm
Power consumption (at 12 V): heating water container: 0.5A
Air flow rate (free blowing): max. 287m³/h
Current: approx. 1mA
Current consumption CP plus (optional): 3mA
Frost Control heating element (optional): max. 0.4A
Pump pressure: max. 2.8bar
System pressure: max. 4.5bar
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
OEM for professional installation only!
The Combi D 6E is structurally identical to the Combi D 6, the only difference being the integrated electric heating elements. The diesel version is equipped with a high-quality burner and therefore reliably heats the vehicle while driving.
· Can also be operated with an empty water tank
· Simple operation with the digital Truma CP plus (iNet ready) control panel or via iNet X System
· Optimum warm air distribution via four air outlets
· 10-litre stainless steel water tank
· Compact and space-saving, various installation options
· Heats the vehicle and water very quickly
· Uses little energy
· Integrated pressure sensor automatically controls the combustion air infeed
· Long service life thanks to efficient combustion control
· Automatic climate control possible in combination with a Truma air conditioner
· Heat Hybrid: integrated electric heating elements for additional electrical power
· 2 in 1: heats your vehicle and heats water at the same time
· For larger vehicles
Energy sources: Diesel as per EN 590
Rated heat output in diesel mode: 1000W/2000W/3000W/4000W/5000W/6000W
Rated heat output in electric mode: 900W/1800W
Rated heat output in mixed mode: max. 6900W
Fuel consumption: 0.1 – 0.6 l/h
Power consumption (at 12 V): operation of heater and water container: 0.4 – 8.1A
Power consumption (at 230 V): 3.9A/7.8A
Water capacity: 10 litres
Heating time (from approx. 15 °C to approx. 60 °C): Water container: approx. 20min.
Heating time (from approx. 15°C to approx. 60°C): Heater and water container acc. to EN 15033: approx. 80min.
Weight: 16.9kg
Dimensions (L x W x H): 510 x 450 x 300 mm
Installation dimensions (minimum dimensions–additional space must be provided for the gas connection. water connections and drain valve (L x W x H) depending on the installation situation): 540 x 500 x 350mm
Power consumption (at 12 V): heating water container: 0.5A
Air flow rate (free blowing): max. 287m³/h
Current: approx. 1mA
Current consumption CP plus (optional): 3mA
Frost Control heating element (optional): max. 0.4A
Pump pressure: max. 2.8bar
System pressure: max. 4.5bar